Preventing plastic pellet loss: measures, and how the frameworks fit together
Plastic pellet loss prevention ➔ where losses happen, which measures work and how EU 2025/2365 and OCS fit in. Read the guide!
Read guide →



Couldn't load pickup availability
Need a custom size or a different version? Send us the key details directly via the form.
D1 has the same Ø 395 mm as the C3 and a little over half its depth. It is the form for wide gully pots that are not deep, and for positions where a full bucket has to be lifted out by hand.
That second reason is underrated. A 70 l bucket full of wet sediment is a two-person lift or a job for equipment. A 40 l bucket in the same pot is often not. Where a site services its own gullies without lifting aids, the smaller volume is a practical advantage rather than a compromise.
Three situations, and only the first is about geometry.
Clear depth is limited. The pot takes the diameter but not 575 mm of depth. Then D1 is the only one of the two that fits.
Extraction is manual. The pot could take a C3, but whoever empties it does so by hand. A lighter full bucket gets emptied on schedule; a heavy one gets postponed.
The pellet load is modest. Where the drain sits away from the main handling area and collects little, 70 l of capacity buys nothing. The insert will need changing on condition long before the bucket fills.
Where none of those apply and the depth is there, C3 uses the same footprint better.
| Feature | Value |
|---|---|
| Bucket | galvanised steel, slotted |
| Diameter | Ø 395 mm |
| Height | 325 mm |
| Volume | approx. 40 l, derived from external dimensions |
| Filter insert | textile, nominal 70 µm, pre-fitted |
| Replacement | insert only |
Regulatory context. EU Regulation 2025/2365 sets obligations for operators handling plastic pellets, and Operation Clean Sweep is a voluntary industry programme. A retention system can support the measures a site puts in place. It does not, on its own, make a site compliant with either, and WINKLER does not certify compliance. What a scheme achieves depends on the full set of measures, the maintenance regime and the documentation behind it. Background is set out in the guide.
Depth, handling weight or a low load. If none of the three applies, C3 uses the pot better.
Yes. The bucket is the durable part and the insert is the consumable. If the load turns out higher than expected, moving to C3 in the same pot is straightforward.
With the same inflow, yes, by volume. Whether that matters depends on whether the bucket or the insert reaches its limit first, and on most drains it is the insert.
These details are taken automatically from the technical table in the product description.
Selection guidance and technical background for choosing and using the product correctly.
Plastic pellet loss prevention ➔ where losses happen, which measures work and how EU 2025/2365 and OCS fit in. Read the guide!
Read guide →Microplastics and tyre wear in stormwater ➔ what a micron rating tells you about retention and what it cannot. Read the guide!
Read guide →Your cart is currently empty.